• Call Us: (602) 438-7101

Hydraulic Motor Fan Driven Heat Exchangers

Home » Hydraulic Motor Fan Driven Heat Exchangers
emmegi-hydraulic-heat-exchanger-family

2000K & KBV – HPV Series 1 – HPV Series 2

Fan speeds for the hydraulic fan driven heat exchanger series can be varied by changing the oil flow rate to the hydraulic motor. As a result, performance values are shown in ranges. Emmegi stocks several different motor types and displacements allowing for maximum flexibility in application and design.

DOWNLOAD CATALOG PDF
Motor Options
emmegi-gerotor-motor

Gerotor Motors

STOCK DISPLACEMENTS

0.218, 0.372, 0.580 cu-in

emmegi-gear-motor

Gear Motors

STOCK DISPLACEMENTS

.0513, 0.879, 1.171, 1.538 cu-in

emmegi-hydraulic-variable-motor

Variable & Reversing

SPEICAL ORDER

Motors with integrated valves for variable speed and/or reversing airflow for cooler clean-out.

emmegi-piston-motor

Piston Motors

SPEICAL ORDER

High effeciency fan drive

2000K & KBV Series Hydraulic Fan Driven Heat Exchangers
emmegi-2000kbv-series-heat-exchangers

2000K & KBV Series Highlights

Small to Medium (2-28 HP) Cooling Applications
2000KBV Models Include 22 or 44 PSI Internal Bypass
Low Profile 2 Fan Model – 2040 2KSBV – Available
Side Facing JIC External Oil Connections
HPV Series 1 Hydraulic Fan Driven Heat Exchangers

HPV Series 1 Highlights

Medium to Large (6-90 HP) Cooling Applications
22 or 44 PSI Internal Bypass Standard
Cooler Stands Vertical Giving These Heat Exchangers a “Small Footprint”
Rear Facing JIC External Oil Connections
emmegi-hpv-series-1-heat-exchangers
HPV Series 2 Hydraulic Fan Driven Heat Exchangers
emmegi-hpv-series-2-heat-exchangers

HPV Series 2 Highlights

Large (65-285) Cooling Applications
22 or 44 PSI Internal Bypass Standard
Lifting Eyes Provided for Ease of Installation
Rear Facing SAE Flange Oil Connections
Technical Data

Integrated Bypass Valve

emmegi-heat-exchangers-bypass-valveNeed for external valves, related fittings, and hoses are eliminated with Emmegi’s fully integrated bypass check valve that protects against excessive back pressure during cold weather start up and intermittent flow surges.

Compatable Fluids

Mineral Oils: HL & HLP
Water-Oil Emulsion
Water – Glycol
Consult Factory for Other Fluids

Ratings

Operating Pressure: 280 PSI
Test Pressure: 500 PSI
Max. Operating Temperature: 248°F